ARVO Meeting Abstracts
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
 QUICK SEARCH:   [advanced]


     


Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Benito, A.
Right arrow Articles by Artal, P.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Benito, A.
Right arrow Articles by Artal, P.
Invest Ophthalmol Vis Sci 2004;45: E-Abstract 1076.
© 2004 ARVO


1076

COMPENSATION OF CORNEAL ABERRATIONS BY THE INTERNAL OPTICS IS BETTER IN HYPEROPIC EYES

A. Benito and P. Artal

Laboratorio de Optica, Universidad de Murcia, Murcia, Spain

Commercial Relationships: A. Benito, None; P. Artal, None.

Grant Identification: MCyT_BFM2001–0391 (Spain).

Abstract

Purpose: We showed that the lens partially compensates for the corneal aberrations in young eyes (Artal et al., Journal of Vision, 1, 1, 2001). In order to better understand the underlying reasons of such compensation, we explored the dependence of the relative aberrations induced by the cornea and the internal media with the refractive error of the subjects.

Methods: We measured both ocular and corneal wave–front aberrations for 6 mm pupil diameter in two groups of young subjects: myopes (n=57; 29.2±7.1 years old) and hyperopes (n=16; 33±7.9 years old). Refractive errors ranged from –8 to +7 D defocus and –3.75 to +5.5 D astigmatism. Ocular aberrations were measured using our own research prototype Hartmann–Shack wave–front sensor, while corneal aberrations were obtained by using a ray–tracing procedure from the elevation maps provided by a corneal topographer. The internal aberrations were calculated subtracting corneal from ocular aberrations, using the center of the pupil for registration. In every eye, we also estimated the distance from the corneal vertex to the pupil center, which is related to {kappa} angle. This angle is highly dependent on the subject’s refractive error.

Results: The average RMSe of the high order ocular aberrations was lower than the corneal RMSc in the two groups: 0.32/0.41 microns (myopes) and 0.26/0.53 microns (hyperopes). The average compensation factor (1– RMSe/RMSc) was higher in the hyperopic group (0.51) than in the myopic group (0.22). This is mainly due to a significant increase of horizontal coma: the average values for cornea/internal were 0.09/–0.1 microns in myopes versus 0.35/–0.3 microns in hyperopes. The average distance from the corneal vertex to the pupil center was also higher in hyperopes (0.26 mm) than in myopes (0.07 mm). Average spherical aberration was similar within all subjects: positive for the cornea (0.19 microns) and negative for the lens (–0.14 microns). The horizontal decentration of the pupil is correlated with both corneal (r2=0.59) and internal (r2=0.65) horizontal coma.

Conclusions: Corneal aberrations are partially compensated by internal aberrations in most young eyes. We found a higher compensation factor in hyperopic eyes, which usually have a larger {kappa} angle. These results supports a simple passive mechanism for the compensation: a displacement of the cornea with positive spherical aberration induces a positive coma, while this same displacement for the lens, with a similar but with opposite sign spherical aberration, induces a negative coma, that nearly cancels that of the cornea.

Key Words: optical properties • refractive surgery: optical quality